MLVT
SKILLS PORTAL
ព្រះរាជាណាចក្រកម្ពុជា · KINGDOM OF CAMBODIA

Cambodian Skills Delivery Model

SEAL National Course Catalogue · MLVT / National Training Board
អត្តសញ្ញាណប័ណ្ណសិក្សាអាស៊ីអាគ្នេយ៍ការរៀនសូត្រពេញមួយជីវិត • អធិបតេយ្យដោយការរចនាSEALSOUTH EAST ASIA LEARNING IDENTIFIERកម្ពុជា២០២៦
54
Sector Frameworks
1,164
Qualifications
15,161
Competency Units
10,938
Elements
41,782
Learning Outcomes
2,822
Assessment Packages

Certificate III in Fire Protection Control

KHQ-ELT3-009 · Delivery Course: KHC-ELT3-009

Level 3 · Technical Certificate 2FULL DEPTH
Australian Equivalent
UEE31025Certificate III in Fire Protection Control
AQF Equivalent
Certificate III
AU Release
1
DSC
This qualification covers the skills and knowledge required to select, install, set up, test, fault find, repair and maintain fire protection systems in multiple, commercial and industrial premises.
Entry Requirements

There are no entry requirements for this qualification.

Packaging Rules

A total of 1060 weighting points comprising: 650 core weighting points listed below; plus 410 general elective weighting points from the general elective units listed below. Choose a total of 410 weighting points elective units from the list below, of which between 0 and 170 weighting points can be taken from Group A; and between 260 and 410 weighting points must be taken from Group B; or all minimum 410 weighting points can be taken from Group B. Up to 170 weighting points of the general elective units Group A , may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. If weighting points are not listed for an imported unit in any other UEE qualification, default weighting will be 10 points. There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume. Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with. Core units Weighting Points UEECD0007 Apply work health and safety regulations, codes and practices in the workplace 20 UEECD0016 Document and apply measures to control WHS risks associated with electrotechnology work* 20 UEECD0019 Fabricate, assemble and dismantle utilities industry components* 40 UEECD0020 Fix and secure electrotechnology equipment* 20 UEECD0025 Lay wiring/cabling and terminate accessories for extra-low voltage (ELV) circuits* 40 UEECD0043 Solve problems in direct current circuits* 80 UEECD0045 Solve problems in multiple path extra-low voltage (ELV) a.c. circuits* 40 UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications* 40 UEECO0027 Engage in communications, security equipment or fire protection work and competency development 60 UEEDV0005 Install and maintain cabling for multiple access to telecommunication services* 80 UEEEC0026 Enter and verify programs for fire protection systems* 40 UEEEC0041 Install fire detection and warning system apparatus* 40 UEEEC0060 Repairs basic electronic apparatus faults by replacement of components* 40 UEEEC0076 Verify compliance and functionality of fire protection system installations* 60 UEERE0001 Apply environmentally and sustainable procedures in the energy sector 20 CPPFES2043 Apply regulations to prevent ozone depleting substance and synthetic greenhouse gas emissions 10 Group A: Imported and common elective units. Weighting Points BSBOPS203 Deliver a service to customers 20 CPCWHS1001 Prepare to work safely in the construction industry 10 HLTAID009 Provide cardiopulmonary resuscitation 10 HLTAID011 Provide First Aid 10 ICTICT214 Operate application software packages 20 UEECD0011 Comply with scheduled and preventative maintenance program processes 20 UEECD0035 Provide basic instruction in the use of electrotechnology apparatus 20 UEECO0002 Maintain documentation 20 UEECO0015 Provide quotations for installation or service jobs 20 UEECO0017 Source and purchase material/parts for installation or service jobs 20 Group B: Qualification elective units. Weighting Points UEECS0033 Use engineering applications software on personal computers 40 UEEDV0006 Install and modify optical fibre performance data communication cabling* 40 UEEDV0008 Install, modify and verify coaxial and structured communication copper cabling* 40 UEEEC0008 Commission large fire protection systems* 40 UEEEC0071 Troubleshoot fire protection systems* 40 UEEEC0075 Troubleshoot single phase input d.c power supplies* 40 UEEIC0002 Assemble, enter and verify operating instructions in microprocessor equipped devices* 20 UEEIC0013 Develop, enter and verify dis

Units packaged in this qualification

40
KHU-ELT-0016Apply work health and safety regulations, codes and practices in the workplaceAU: UEECD0007KHU-ELT-0025Document and apply measures to control WHS risks associated with electrotechnology workAU: UEECD0016KHU-ELT-0028Fabricate, assemble and dismantle utilities industry componentsAU: UEECD0019KHU-ELT-0029Fix and secure electrotechnology equipmentAU: UEECD0020KHU-ELT-0034Lay wiring/cabling and terminate accessories for extra-low voltage (ELV) circuitsAU: UEECD0025KHU-ELT-0052Solve problems in direct current circuitsAU: UEECD0043KHU-ELT-0054Solve problems in multiple path extra-low voltage (ELV) a.c. circuitsAU: UEECD0045KHU-ELT-0060Use drawings, diagrams, schedules, standards, codes and specificationsAU: UEECD0051KHU-ELT-0090Engage in communications, security equipment or fire protection work and competency developmentAU: UEECO0027KHU-ELT-0129Install and maintain cabling for multiple access to telecommunication servicesAU: UEEDV0005KHU-ELT-0164Enter and verify programs for fire protection systemsAU: UEEEC0026KHU-ELT-0179Install fire detection and warning system apparatusAU: UEEEC0041KHU-ELT-0198Repairs basic electronic apparatus faults by replacement of componentsAU: UEEEC0060KHU-ELT-0214Verify compliance and functionality of fire protection system installationsAU: UEEEC0076KHU-ELT-0478Apply environmentally and sustainable procedures in the energy sectorAU: UEERE0001KHU-CPP-0150Apply regulations to prevent ozone depleting substance and synthetic greenhouse gas emissionsAU: CPPFES2043KHU-BSB-0206Deliver a service to customersAU: BSBOPS203KHU-CON-0604Prepare to work safely in the construction industryAU: CPCWHS1001KHU-HLT-0065Provide cardiopulmonary resuscitationAU: HLTAID009KHU-HLT-0067Provide First AidAU: HLTAID011KHU-ICT-0192Operate application software packagesAU: ICTICT214KHU-ELT-0020Comply with scheduled and preventative maintenance program processesAU: UEECD0011KHU-ELT-0044Provide basic instruction in the use of electrotechnology apparatusAU: UEECD0035KHU-ELT-0074Maintain documentationAU: UEECO0002KHU-ELT-0080Provide quotations for installation or service jobsAU: UEECO0015KHU-ELT-0082Source and purchase material/parts for installation or service jobsAU: UEECO0017KHU-ELT-0124Use engineering applications software on personal computersAU: UEECS0033KHU-ELT-0130Install and modify optical fibre performance data communication cablingAU: UEEDV0006KHU-ELT-0132Install, modify and verify coaxial and structured communication copper cablingAU: UEEDV0008KHU-ELT-0146Commission large fire protection systemsAU: UEEEC0008KHU-ELT-0209Troubleshoot fire protection systemsAU: UEEEC0071KHU-ELT-0213Troubleshoot single phase input d.c power suppliesAU: UEEEC0075KHU-ELT-0331Assemble, enter and verify operating instructions in microprocessor equipped devicesAU: UEEIC0002KHU-ELT-0342Develop, enter and verify discrete control programs for programmable controllersAU: UEEIC0013KHU-ELT-0304Enter a classified hazardous area to undertake work related to electrical equipmentAU: UEEHA0004KHU-ELT-0312Determine the explosion-protection requirements to meet a specified classified hazardous areaAU: UEEHA0022KHU-ELT-0315Install explosion-protected equipment and associated apparatus and wiring systemsAU: UEEHA0025KHU-ELT-0316Maintain equipment associated with hazardous areasAU: UEEHA0026KHU-ELT-0529Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiringAU: UEERL0004KHU-ELT-0530Locate and rectify faults in low voltage (LV) electrical equipment using set proceduresAU: UEERL0005
SEAL — South East Asia Learning Identifier & Skills Portal · Prepared for MLVT Executive approval and TVET institute review · Derived from the Australian National Training Register (training.gov.au, CC-BY) and aligned to the Cambodian Qualifications Framework and DSC Standard Training Packages · Delivered via Gibble SMS · July 2026