MLVT
SKILLS PORTAL
ព្រះរាជាណាចក្រកម្ពុជា · KINGDOM OF CAMBODIA

Cambodian Skills Delivery Model

SEAL National Course Catalogue · MLVT / National Training Board
អត្តសញ្ញាណប័ណ្ណសិក្សាអាស៊ីអាគ្នេយ៍ការរៀនសូត្រពេញមួយជីវិត • អធិបតេយ្យដោយការរចនាSEALSOUTH EAST ASIA LEARNING IDENTIFIERកម្ពុជា២០២៦
54
Sector Frameworks
1,164
Qualifications
15,161
Competency Units
10,938
Elements
41,782
Learning Outcomes
2,822
Assessment Packages

Certificate IV in Hazardous areas - Electrical

KHQ-ELT4-017 · Delivery Course: KHC-ELT4-017

Level 4 · Technical Certificate 3FULL DEPTH
Australian Equivalent
UEE42622Certificate IV in Hazardous areas - Electrical
AQF Equivalent
Certificate IV
AU Release
1
DSC
This qualification provides competencies to supervise selection, installation, commissioning maintenance and testing of explosion-protected equipment and systems for control and monitoring of plant and processes. The qualification provides competencies in working with explosion-protection techniques. It includes requirements and competencies to select, install, set up, test, fault find, repair and maintain stand-alone renewable energy equipment and systems. No licensing, legislative or certification requirements apply to this qualification at the time of publication.
Entry Requirements

The entry requirement for this qualification is: Certificate III in Electrotechnology Electrician or a current ‘Unrestricted Electricians Licence’ or its equivalent issued in an Australian state or territory.

Packaging Rules

A total of 440 weighting points comprising: 200 core weighting points listed below; plus 240 general elective weighting points from the general elective units listed below. Choose a total of 240 weighting points elective units from the list below, of which between 0 and 60 weighting points can be taken from Group A; between 0 and 80 weighting points can be taken from Group B; and between 140 and 240 can be taken from Group C (or all 240 elective weighting points can be taken from Group C). Up to 60 weighting points of the general elective unitsGroup A , may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC). There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume. Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with. Core units Weighting Points UEECD0010 Compile and produce an energy sector detailed report 60 UEECD0024 Implement and monitor energy sector WHS policies and procedures 20 UEECD0027 Participate in development and follow a personal competency development plan 20 UEEHA0004 Enter a classified hazardous area to undertake work related to electrical equipment 40 UEEHA0022 Determine the explosion-protection requirements to meet a specified classified hazardous area* 40 UEERE0015 Implement and monitor energy sector environmental and sustainable policies and procedures 20 Group A: Imported and common elective units Weighting Points BSBOPS203 Deliver a service to customers 20 ICTICT214 Operate application software packages 20 UEECD0011 Comply with scheduled and preventative maintenance program processes 20 UEECD0035 Provide basic instruction in the use of electrotechnology apparatus 20 UEECO0002 Maintain documentation 20 UEECO0015 Provide quotations for installation or service jobs 20 UEECO0017 Source and purchase material/parts for installation or service jobs 20 Group B: General elective units Weighting Points UEECD0050 Use and maintain the integrity of a portable gas detection device* 20 UEEHA0024 Inspect, maintain and fit plugs/couplers for reeling, trailing and flexible cables - coal mining* 60 UEEHA0030 Repair reeling, trailing and flexible cables used in coal mining 60 UEEHA0031 Supervise repair and overhaul of explosion-protected equipment type flameproof (Ex d)* 60 UEEHA0032 Supervise repair and overhaul of explosion-protected equipment type increased safety (Ex e)* 60 UEEHA0033 Supervise repair and overhaul of explosion-protected equipment type intrinsically safe (Ex i)* 60 UEEHA0034 Supervise repair and overhaul of explosion-protected equipment type pressurised (Ex p)* 60 UEEHA0035 Supervise repair and overhaul of explosion-protected rotating machines* 60 UEEHA0036 Test reeling, trailing and flexible cables and their attachments used in coal mining* 60 UEEHA0037 Verify compliance of repaired reeling, trailing and flexible cables and attachments - coal mining* 60 UEEHA0039 Supervise repair and overhaul of explosion-protected equipment type Group III (‘t’)* 60 Group C: General elective units Weighting Points UEEHA0020 Conduct detailed inspection of electrical installations for hazardous areas* 40 UEEHA0023 Develop and manage periodic electrical inspection and maintenance programs for hazardous areas* 20 UEEHA0025 Install

Units packaged in this qualification

31
KHU-ELT-0019Compile and produce an energy sector detailed reportAU: UEECD0010KHU-ELT-0033Implement and monitor energy sector WHS policies and proceduresAU: UEECD0024KHU-ELT-0036Participate in development and follow a personal competency development planAU: UEECD0027KHU-ELT-0304Enter a classified hazardous area to undertake work related to electrical equipmentAU: UEEHA0004KHU-ELT-0312Determine the explosion-protection requirements to meet a specified classified hazardous areaAU: UEEHA0022KHU-ELT-0484Implement and monitor energy sector environmental and sustainable policies and proceduresAU: UEERE0015KHU-BSB-0206Deliver a service to customersAU: BSBOPS203KHU-ICT-0192Operate application software packagesAU: ICTICT214KHU-ELT-0020Comply with scheduled and preventative maintenance program processesAU: UEECD0011KHU-ELT-0044Provide basic instruction in the use of electrotechnology apparatusAU: UEECD0035KHU-ELT-0074Maintain documentationAU: UEECO0002KHU-ELT-0080Provide quotations for installation or service jobsAU: UEECO0015KHU-ELT-0082Source and purchase material/parts for installation or service jobsAU: UEECO0017KHU-ELT-0059Use and maintain the integrity of a portable gas detection deviceAU: UEECD0050KHU-ELT-0314Inspect, maintain and fit plugs/couplers for reeling, trailing and flexible cables - coal miningAU: UEEHA0024KHU-ELT-0320Repair reeling, trailing and flexible cables used in coal miningAU: UEEHA0030KHU-ELT-0321Supervise repair and overhaul of explosion-protected equipment type flameproof (Ex d)AU: UEEHA0031KHU-ELT-0322Supervise repair and overhaul of explosion-protected equipment type increased safety (Ex e)AU: UEEHA0032KHU-ELT-0323Supervise repair and overhaul of explosion-protected equipment type intrinsically safe (Ex i)AU: UEEHA0033KHU-ELT-0324Supervise repair and overhaul of explosion-protected equipment type pressurised (Ex p)AU: UEEHA0034KHU-ELT-0325Supervise repair and overhaul of explosion-protected rotating machinesAU: UEEHA0035KHU-ELT-0326Test reeling, trailing and flexible cables and their attachments used in coal miningAU: UEEHA0036KHU-ELT-0327Verify compliance of repaired reeling, trailing and flexible cables and attachments - coal miningAU: UEEHA0037KHU-ELT-0329Supervise repair and overhaul of explosion-protected equipment type Group III ('t')AU: UEEHA0039KHU-ELT-0310Conduct detailed inspection of electrical installations for hazardous areasAU: UEEHA0020KHU-ELT-0313Develop and manage periodic electrical inspection and maintenance programs for hazardous areasAU: UEEHA0023KHU-ELT-0315Install explosion-protected equipment and associated apparatus and wiring systemsAU: UEEHA0025KHU-ELT-0316Maintain equipment associated with hazardous areasAU: UEEHA0026KHU-ELT-0317Manage continuous supervision inspection of electrical installations for hazardous areasAU: UEEHA0027KHU-ELT-0319Plan electrical installations for hazardous areasAU: UEEHA0029KHU-ELT-0328Conduct visual and close inspection of electrical installations for hazardous areasAU: UEEHA0038
SEAL — South East Asia Learning Identifier & Skills Portal · Prepared for MLVT Executive approval and TVET institute review · Derived from the Australian National Training Register (training.gov.au, CC-BY) and aligned to the Cambodian Qualifications Framework and DSC Standard Training Packages · Delivered via Gibble SMS · July 2026