MLVT
SKILLS PORTAL
ព្រះរាជាណាចក្រកម្ពុជា · KINGDOM OF CAMBODIA

Cambodian Skills Delivery Model

SEAL National Course Catalogue · MLVT / National Training Board
អត្តសញ្ញាណប័ណ្ណសិក្សាអាស៊ីអាគ្នេយ៍ការរៀនសូត្រពេញមួយជីវិត • អធិបតេយ្យដោយការរចនាSEALSOUTH EAST ASIA LEARNING IDENTIFIERកម្ពុជា២០២៦
54
Sector Frameworks
1,164
Qualifications
15,161
Competency Units
10,938
Elements
41,782
Learning Outcomes
2,822
Assessment Packages

Conduct and report on advanced and final inspections of Class 2 to 9 buildings to three storeys

KHU-CON-0099

Australian Equivalent
CPCCBS6115
Elements
3
Learning Outcomes
12

This unit of competency specifies the skills and knowledge required to conduct and report on advanced and final inspections that occur after constructing the structural elements of commercial buildings included in Classes 2 to 9, as defined in the National Construction Code (NCC), up to three storeys and not exceeding 2,000 square metres in floor area. The unit includes planning and conducting inspections, reporting on issues of non-compliance, preparing certificates of compliance and issuing occupancy permissions according to legislative and regulatory requirements. This unit is suitable for building surveyors who draw on their broad theoretical knowledge and technical skills to conduct mandated inspections of buildings included in Class 2 to 9 at the advanced and final stages of construction. Inspections are those specified in the building approval documentation for the project includi

Elements & Learning Outcomes

3
E1Interpret compliance requirements for building included in Class 2 to 9.
0099.E1.O1Access and interpret approved building design drawings and specifications for building and consult with relevant persons to confirm compliance of any variations from deemed-to-satisfy provisions.
0099.E1.O2Assess building features detailed in approved drawings to check compliance with NCC and regulatory requirements.
E2Plan building inspections.
0099.E2.O1Review building approval documentation to identify requirements for specific additional inspections.
0099.E2.O2Identify need for expert advice and engage relevant specialist consultant.
0099.E2.O3Obtain required equipment to inspect building and apply work health and safety (WHS) requirements to inspection activities according to workplace requirements.
0099.E2.O4Schedule advanced and final inspections according to building and regulatory requirements and notify relevant persons.
E3Inspect and report compliance of building included in Class 2 to 9.
0099.E3.O1Conduct advanced and final inspection of building according to regulatory and workplace requirements.
0099.E3.O2Assess building features against compliance requirements and approved drawings.
0099.E3.O3Document and report details of non-compliant features according to regulatory and workplace requirements.
0099.E3.O4Discuss non-compliant features of building with relevant persons and negotiate work required to remedy non-compliances according to workplace requirements.
0099.E3.O5Negotiate timeframe for remedial action and further inspection and report any failure to comply according to regulatory and workplace requirements.
0099.E3.O6Prepare and process certificate of compliance and issue occupancy permission according to regulatory and workplace requirements.
SEAL — South East Asia Learning Identifier & Skills Portal · Prepared for MLVT Executive approval and TVET institute review · Derived from the Australian National Training Register (training.gov.au, CC-BY) and aligned to the Cambodian Qualifications Framework and DSC Standard Training Packages · Delivered via Gibble SMS · July 2026