Create detailed designs for fire systems' water supplies

KHU-CON-0567

Australian Equivalent
CPCSFS5009
Elements
4
Learning Outcomes
16

This unit of competency specifies the outcomes required to obtain, process and set up drawings for the detailed design of water supplies for fire systems. The unit also involves assessing and selecting component requirements, setting out the locations of components and creating final notated drawings. This unit of competency supports the role of fire systems designers with responsibility for creating detailed designs for water supplies for fire systems. In some jurisdictions, this unit of competency may form part of accreditation, licensing, legislative, regulatory or certification requirements.

Elements & Learning Outcomes

4
E1Confirm water-based fire systems designs.
0567.E1.O1Request, receive, name and file relevant project drawings and documentation according to workplace procedures.
0567.E1.O2Confirm details and dimensions and to assess water supply installation risks and constraints.
0567.E1.O3Notate the exact location of fire system components on detailed design drawings according to relevant codes and standards.
0567.E1.O4Name, file and back up the detailed design drawings according to workplace procedures.
E2Calculate pipe sizes and pump and tank requirements.
0567.E2.O1Determine the initial fire flow demands for the site based on the occupancy classifications.
0567.E2.O2Analyse water flow and pressure test results to establish the minimum levels of available supply in accordance with local jurisdictional requirements.
0567.E2.O3Determine and analyse the town main water capabilities for the fire services serving the site to identify if fire pumps and fire tanks are required.
0567.E2.O4Consider options for cost-effective and efficient solutions with reference to manufacturer specifications for the performance of components and according to workplace policies.
E3Lay out the water supply design.
0567.E3.O1Identify methodologies used in making town main connections.
0567.E3.O2Determine and notate the most efficient and workable layout and location of water supply components on the drawings according to workplace procedures.
0567.E3.O3Calculate, check and notate dimensions on the drawings according to relevant codes and standards and component manufacturer's recommendations and workplace procedures.
0567.E3.O4Determine the locations of backflow prevention devices and their accessibility.
0567.E3.O5Review proposed locations of booster connections with local fire authority.
E4Submit drawings for approval and finalise design process.
0567.E4.O1Submit water supply design drawings to relevant personnel within the scheduled timeframe.
0567.E4.O2Make or negotiate required amendments to design drawings as required.
0567.E4.O3Process and distribute final approved design drawings according to relevant codes and standards and component manufacturer's recommendations workplace requirements.
SEAL — South East Asia Learning Identifier & Skills Portal · Prepared for MLVT Executive approval and TVET institute review · Derived from the Australian National Training Register (training.gov.au, CC-BY) and aligned to the Cambodian Qualifications Framework and DSC Standard Training Packages · Delivered via Gibble SMS · July 2026