Install, commission, service and maintain air conditioning systems

KHU-ELT-0477

Australian Equivalent
UEERA0099
Elements
7
Learning Outcomes
7

This unit involves the skills and knowledge required to safely and effectively install, commission, service and maintain air conditioning systems. It includes the ability to source relevant data and schematics; install components, pipe work, accessories and controls to create a functional air conditioning system. It covers selecting installing and replacing cables within air conditioning equipment operating at voltages up to 500 volt (V) alternating current (a.c.), according to relevant State/Territory legislation and regulations. Commissioning the system to ensure it operates at the specified design conditions, locating and rectifying faults and carrying out routine maintenance procedures. The skills and knowledge of this unit of competency will be applied by refrigeration and air conditioning technicians during the installation, commissioning and servicing of air conditioning systems.

Elements & Learning Outcomes

7
E1Prepare to install air conditioning systems
0477.E1.O1WHS/OHS risk control measures and procedures for carrying out the work are obtained and implemented in accordance with workplace procedures
E2Select, install, replace and terminate low voltage (LV) and extra-low voltage (ELV) cables within air conditioning equipment.
0477.E2.O1Cable conductor sizes are selected to meet the equipment manufacturer specifications, current-carrying capacity requirements
E3Install non-ducted split air conditioning systems
0477.E3.O1All required major components are securely mounted in the locations identified by the documentation or the supervisor in accordance with workplace procedures
E4Install ducted split air conditioning systems
0477.E4.O1Major components are securely mounted in the locations identified by the documentation or the supervisor in accordance with workplace procedures
E5Commission air conditioning systems
0477.E5.O1Air conditioning system is charged with the appropriate type and quantity of refrigerant in accordance with industry standards, relevant codes of practices and workplace procedures
E6Locate and rectify faults and carry out maintenance on air conditioning systems
0477.E6.O1Fault diagnosis is carried out in accordance with industry standards, relevant codes of practices and workplace procedures
E7Complete work and report activities
0477.E7.O1WHS/OHS risk control measures continue to be applied in accordance with workplace procedures
SEAL — South East Asia Learning Identifier & Skills Portal · Prepared for MLVT Executive approval and TVET institute review · Derived from the Australian National Training Register (training.gov.au, CC-BY) and aligned to the Cambodian Qualifications Framework and DSC Standard Training Packages · Delivered via Gibble SMS · July 2026