Lesson 3.3 — Reading Circuit Diagrams

EDC Supply230 V · 50 HzkWhMeterMain boardMCB + RCD 30 mALighting circuit 6 ASocket circuit 16 AAir-con circuit 20 AColour code (Cambodia / IEC):Line (L) — brown/redNeutral (N) — blue/blackEarth (PE) — green-yellowEvery final circuit protected by an MCB sized to the cable; whole installation protected by a 30 mA RCD.

A building installation reads like a tree: supply → meter → main board → final circuits. Learn the symbols for switch, socket, lamp, MCB, RCD and earth, then practise translating a floor plan into a wiring schedule: how many circuits, what breaker sizes, what cable runs. The manual's rule of thumb for a small Cambodian home: lighting 6 A / 1.5 mm², sockets 16 A / 2.5 mm², air-con 20 A / 2.5 mm² dedicated.

Evidence task

Upload your wiring schedule for the practice floor plan.

SEAL — South East Asia Learning Identifier & Skills Portal · Prepared for MLVT Executive approval and TVET institute review · Derived from the Australian National Training Register (training.gov.au, CC-BY) and aligned to the Cambodian Qualifications Framework and DSC Standard Training Packages · Delivered via Gibble SMS · July 2026