Install dry wall passive fire-rated systems

KHU-CON-0375

Australian Equivalent
CPCCWC3003
Elements
7
Learning Outcomes
32

This unit of competency specifies the outcomes required to select and install dry wall fire-rated systems to walls and ceilings. A person working at this level would be expected to take responsibility for organising and completing tasks assigned to them without close supervision. A person working at this level would be expected to take responsibility for organising and completing tasks assigned to them without close supervision. Completion of the general construction induction training program specified by the model Code of Practice for Construction Work is required for any person who is to carry out construction work. Achievement of CPCWHS1001 Prepare to work safely in the construction industry meets this requirement. No licensing, legislative or certification requirements apply to this unit at the time of publication.

Elements & Learning Outcomes

7
E1Plan and prepare.
0375.E1.O1Read and interpret work instructions and plan sequence of work.
0375.E1.O2Plan all work to comply with laws and regulations, the National Construction Code (NCC), Australian Standards, work health and safety (WHS) and environmental requirements, manufacturers’ specifications, and workplace requirements.
0375.E1.O3Plan all work strictly within the manufacturer’s fire-rating design, so that fire-rating criteria are always met.
0375.E1.O4Select and use personal protective equipment (PPE) for each stage of the task.
0375.E1.O5Inspect work site, assess hazards and apply risk controls, including required signage and barricades.
0375.E1.O6Select tools and equipment, check for serviceability and report any faults that may affect the safe operation of the equipment, tag equipment and set aside.
0375.E1.O7Select materials required for task, calculate quantities, handle safely and prepare and position ready for use.
E2Line timber stud wall using fire-rated system.
0375.E2.O1Determine whether structure of the timber wall is for load or non-load bearing.
0375.E2.O2Select manufacturer’s fire-rating design for the timber stud wall.
0375.E2.O3Set out materials and space fixings to manufacturer’s fire-rating design.
0375.E2.O4Fix material and complete penetrations.
0375.E2.O5Finish joints to exposed face sheet layers using fire-rated materials and procedures to manufacturer’s fire-rating design.
E3Construct steel stud fire-rated partition system.
0375.E3.O1Select manufacturer’s fire-rating design for the steel stud wall.
0375.E3.O2Determine the fixing requirements for the steel stud wall, as designed to meet fire test criteria.
0375.E3.O3Secure deflection heads and apply sealant.
0375.E3.O4Setout material, meeting the manufacturer’s fire-rating design.
0375.E3.O5Space fixings, fix materials and complete penetrations.
0375.E3.O6Finish joints to exposed face sheet layers using fire-rated materials and procedures to manufacturer’s fire-rating design.
E4Construct fire-rated shaft wall system.
0375.E4.O1Select materials to manufacturer’s fire-rating design and fix components to precise clearances.
0375.E4.O2Set out materials and complete penetrations.
0375.E4.O3Finish joints to exposed face sheet layers using fire-rated materials and procedures to manufacturer’s fire-rating design.
E5Line timber joist ceiling using fire-rated system.
0375.E5.O1Check ceiling substrate and line to manufacturer’s fire-rating design.
0375.E5.O2Select fixings and apply lining.
0375.E5.O3Space fixings at correct intervals.
0375.E5.O4Complete penetrations.
0375.E5.O5Finish joints to exposed face sheet layers using fire-rated materials and procedures to manufacturer’s fire-rating design.
E6Construct suspended ceiling with a fire-rating system.
0375.E6.O1Select materials and choose fixings for manufacturer’s fire-rating design for fire-rated ceiling.
0375.E6.O2Construct ceiling flat, true, level and structurally sound.
0375.E6.O3Complete penetrations.
0375.E6.O4Finish joints to exposed face sheet layers using fire-rated materials and procedures to manufacturer’s fire-rating design.
E7Clean up.
0375.E7.O1Clear work area and dispose of, reuse or recycle materials.
0375.E7.O2Clean, check, maintain and store tools and equipment in accordance with manufacturers’ specifications.
SEAL — South East Asia Learning Identifier & Skills Portal · Prepared for MLVT Executive approval and TVET institute review · Derived from the Australian National Training Register (training.gov.au, CC-BY) and aligned to the Cambodian Qualifications Framework and DSC Standard Training Packages · Delivered via Gibble SMS · July 2026