Design waterproofing to internal wet area

KHU-CON-0399

Australian Equivalent
CPCCWP5003
Elements
4
Learning Outcomes
25

This unit of competency specifies the skills and knowledge required for designing waterproofing systems to internal wet areas for buildings. The unit applies to Class 1 and 10 Buildings, and Class 2 to 9 Buildings. The unit includes planning and preparing to design waterproofing systems, analysing risk, designing waterproofing and evaluating the design of the waterproofing system solution. The unit is suitable for builders, building designers, architects, building surveyors, waterproofing design specialists and consultants, engineers and other design specialists. Licensing, legislative, regulatory or certification requirements may apply to this unit. Relevant work health and safety (WHS) state and territory regulatory authorities should be consulted to confirm jurisdictional requirements.

Elements & Learning Outcomes

4
E1Plan and prepare.
0399.E1.O1Identify internal wet areas and waterproofing requirements in accordance with National Construction Code (NCC) and from drawings and specifications.
0399.E1.O2Identify types of construction and their permeability to water and moisture, including concrete, masonry and framing.
0399.E1.O3Determine the use of the wet area to be waterproofed and categorise as low, medium or high usage, including finishes in accordance with client’s needs and use of wet area.
0399.E1.O4Identify shower type to inform the design.
0399.E1.O5Identify extent of membrane application to inform the design.
0399.E1.O6Identify egress points to inform the design.
0399.E1.O7Identify potential water ingress points for the construction.
0399.E1.O8Determine the scope of project, conditions to be managed and waterproofing requirements to be achieved.
0399.E1.O9Determine outfalls to suit water inlet and use of area.
E2Carry out risk analysis.
0399.E2.O1Assess risk of water bearing to full extent of application and the effects of charged dynamic water movement in high usage conditions.
0399.E2.O2Assess risks of defects in the waterproofing systems.
0399.E2.O3Assess consequence of water and moisture ingress into space outside of the wet area.
0399.E2.O4Assess and manage interstitial condensation within building elements as part of design.
0399.E2.O5Determine effects of water and moisture on building elements.
0399.E2.O6Determine feasibility of repair and maintenance of the waterproofing system.
0399.E2.O7Identify site environmental conditions according to approved plans, including surface and sub-surface drainage.
E3Carry out waterproofing design.
0399.E3.O1Confirm type of wet area for use and confirm shower type and components.
0399.E3.O2Confirm other fittings and fixtures in internal wet area, including bath type and position, vanity type and position, toilet/bidet type and position.
0399.E3.O3Identify internal wet area waterproofing systems available to suit the design that are appropriate for the conditions.
0399.E3.O4Develop design requirements for level of risk to moisture and water exposure in consultation with stakeholders.
0399.E3.O5Provide a scope for the installation of the internal wet area waterproofing system, including substrate considerations and compatibility with finishes, in accordance with specifications.
0399.E3.O6Provide quality assurance inspection protocols for internal wet area waterproofing system installation, including substrate assessment for suitability, compliance of membrane installation with manufacturers’ specifications, completion inspection processes, and repair and maintenance plan.
E4Evaluate waterproofing design.
0399.E4.O1Assess effectiveness of internal wet area waterproofing systems design for suitability with site conditions and consequential effect where water bears at the maximum designed level, defects are present in the waterproofing system and defects impact the usage of adjoining areas.
0399.E4.O2Review repair and maintenance plan of internal wet area waterproofing system.
0399.E4.O3Record and report on compliant internal wet area waterproofing design solutions to stakeholders in accordance with service conditions and manufacturers’ specifications, Australian Standards, and NCC performance requirements.
SEAL — South East Asia Learning Identifier & Skills Portal · Prepared for MLVT Executive approval and TVET institute review · Derived from the Australian National Training Register (training.gov.au, CC-BY) and aligned to the Cambodian Qualifications Framework and DSC Standard Training Packages · Delivered via Gibble SMS · July 2026